At Hunkar our focus is to detect and eliminate potential process problems before bad parts can be produced. Hunkar designs and builds a wide variety of blow molding controls, injection controls, sensors and transducers, valves, as well as preemptive data acquisition systems and equipment that can enhance virtually every plastics molding process.
Hunkar Gold Standard™ Sensors and Transducers: Where Precision and Increased Profits Begin
Often, plastics molders use sensors and transducers whose accuracy and reliability differ greatly unit to unit. This is usually due to wide tolerance variability. To the molder, this requires re-calibrating the machine to a new sensor whenever one is replaced. Additionally, it can mean that a sensor may not be precise enough to assure acceptable tight control limits required for all jobs. Hunkar Gold-Standard instrument grade, National Institute of Standards and Technology (NIST) traceable sensors and transducers are the best solution.
Hunkar Gold-Standard Sensors are at least 10-times more accurate than typical industrial grade sensors. Gold-Standard sensors eliminate the need to recalibrate your machine during future sensor replacement, because each sensor is electrically identical. You'll also enjoy significantly longer sensor life, due to Hunkar's durable construction. Other Gold-Standard benefits include:
Hunkar Gold-Standard Accuracy provides required third party, independent, traceable data for quality program support such as: QS 9001, ISO 9000 and ISO 14000. Every Hunkar Gold-Standard sensor and transducer is lab tested according to strict procedures to ensure absolute uniformity; traceable to NIST standards.
| Sensor Type | Hunkar Gold-Standard | Sensor Outputs |
|---|---|---|
| Oil Pressure | +/- 0.70 PSI | 14 MV @ 3000 psi |
| Melt Pressure | +/- 0.70 PSI | 3.3 MV @ Max |
| Air Pressure | +/- 0.70 PSI | 3.3 MV @ Max |
| Cavity Pressure | +/- :% Full Scale | 14 MV @ 3000 psi |
| Mold Temperature | +/- 0.5° F | J-Style Thermocouple |
| Ram Position | +/- 0.005 Inches | 0-10 VDC |
| Time Intervals | +/- 0.001 Seconds | 110 VAC, 220 VAC, or 24 VDC |
Consider Gold-Standard Preamplifiers and Analog to Digital Converters to complete the chain of full data accuracy and accountability. Also please inquire about the accuracy, reliability and ease of use of Hunkar parison program controls, injection molding controls, and Smart data collection applications and systems with plug & play modules.